Yuanben Sensor Engaged in magnetoelectric sensor design & production, a professional high-tech magnetic sensor manufacturer.
Description
The measurement range of the rotary sensor can reach 360°, and it can be programmed for the analog version with a step of ±15°. The non-contact Hall technology has almost unlimited sensor lifespan as there is no wear on the sensing element. Various configurations make this product easy to install on vehicles.
The high IP protection level, shock and vibration resistance, as well as high electromagnetic compatibility make these products suitable for many mobile hydraulic applications. Aimed at ensuring the provision of powerful and high-performance solutions for applications such as agricultural machinery, construction machinery, and material handling equipment
Characteristics
It has a long service life. The non-contact measurement based on Hall principle is extremely reliable
The Angle measurement range is between 30° and 120°
IP67 protection rating, suitable for harsh environmental conditions
Operating temperature range: -40 °C to +85 °C
Resolution: 0.1°
Various current or voltage output signals
Infinite short-circuit protection
It can be provided together with the operating lever for easy connection
EMC stability for the motor vehicle field, with on-site tolerance of 200 V/m
Ball bearings (sliding bearings are optional)
Application
In mobile machinery, cranes, excavators, ships, mobile and fixed garbage compactors, valve controllers, robotics, wind turbines or large medical equipment.
Technical parameters
Functional characteristics |
|||
Induction Angle (Θ) |
Unknown error (error) |
Accuracy (error) |
|
120 (±60) |
+ / - 1.0 |
+ / - 1.6 |
|
Electrical characteristics |
|||
Parameters |
Low-voltage model |
||
The SENSINC principle |
Contact FREE HALL |
||
Power supply voltage |
5±0.5V DC |
||
Power supply current |
Maximum 20mA |
||
Power supply current (during the short circuit from QUTPUT to ground) |
Maximum 25mA |
||
Output |
0.5 to 4.5V ratio |
||
QUTPUT signal delay |
4MS (typical value) |
||
Overvoltage protection |
10V DC |
||
Reverse polarity protection |
-10V DC |
||
The QUTPUT is short-circuited to ground |
Continuous |
||
Circuit protection |
|||
QUTPUT load resistor |
10Ω (typical value) |
PNP output |
|
(Pull Don to the ground) |
|||
EMI radiation immunity |
100V/m ISO1452-2 ranges from 200MHz to 100 Hz |
||
EMI transmission immunity |
100m ISO1452-2 ranges from 1 to 200MHz |
||
Electromagnetic compatibility |
Exceed the CE regulations |
||
Environmental characteristics |
|||
Working temperature |
-40 to 125°C |
||
Protection grade |
IP 67 accumulation. Execute DIN-40050 |
||
Product lifespan |
>3 Y-axis ears, 35 M cycle, no side load |
||
VEDIA Compatibility |
COMNON AUTO FLUIDS |
||
Vehicular VIERATION |
Peak value of 20G |
||
Mechanical shock |
50GPEAK |
Get in touch with us