loading

Yuanben Sensor Engaged in magnetoelectric sensor design & production, a professional high-tech magnetic sensor manufacturer.

Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 1
Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 2
Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 3
Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 4
Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 1
Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 2
Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 3
Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 4

Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001

    oops...!

    no product data.

    Go to homepage

    Description

    The MPSS non-contact magnetic safety switch is widely used in industrial safety interlock systems. It features a PPS engineering plastic housing with a protection level of IP67, ensuring stable and reliable performance. At the same time, non-contact coded magnetic safety switches can be customized according to special requirements. The wire and wire length, stainless steel shell material, etc. can be determined according to the customer's requirements.

     Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 5

    Characteristics

    It has excellent impact resistance and vibration resistance, making it suitable for harsh application environments.

    The engineering plastic PPS shell is strong and durable.

    There is no mechanical wear and it has a long service life.

    The protection level reaches IP67.

    The square features a small and simple design, quick installation, integrated cable insertion, and flexible installation.

    Working distance: Safe close distance Sao: up to 7mm; Safety cut-off range Sar: Maximum 20mm

     Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 6

     Application

    This sensor can be used for safety door and position monitoring in safety interlock systems, top cover and movable door protection, or for monitoring of general important positions or protection devices, such as injection molding machines, machining centers, etc. Monitoring of door fixers, covers, replica doors, rolling shutters and security doors in key laboratories, testing and measurement industries or places.

     Safety sensor-non-contact magnetic safety switch-MPSS-3626-072-001 7

     Technical Parameters

     

    Sensor structure

    Sensors with excitation drive elements

    Principle

    magnetic

    The number of contacts

    N.O, 2; Or N.O., 1 and N.C., 1

    Number of signal contacts

    0

    Safe closing distance Sao

    7 millimeters

    Safe Cut-off Distance Sar

    20 millimeters

    The activated sensor surface

    1

    Activation direction

    3

     

    Safety technical parameters:

    The B10d value

    Switch action 2 x 107 (small load)

    Structural type

    Structural Type 4 (EN ISO 14119)

    The code level of the excitation element

    Low coding level (EN ISO 14119)

    Security when errors occur

    This switch has no internal detection function and cannot present a safe state when a fault occurs.

    Fault detection is performed by the connected safety-related logic unit.

     

    Function:

    Security series

    Through Flexi Loop (including diagnosis)

    Connection method

    Electrical, M8,4 pin

     

    Electrical parameters:

    Output mode

    Reed contact

    Switching voltage

    30 V DC

    Switching current

    ≤ 100 mA

     

    Mechanical data:

    Shape structure

    Square

    Dimensions (width * Height * depth)

    26 millimeters x 36 millimeters x 13 millimeters

    Weight

    0.12 kilograms

    Shell material

    Glass fiber reinforced PPS

     

    Environmental parameters:

    Housing prevention category

    IP67 (IEC 60529)

    Working temperature

    –20 °C ... +60 °C

    Storage temperature range

    –20 °C ... +60 °C

    Anti-vibration property

    10 Hertz... 55 Hertz, 1 millimeter (EN 60947-5-3)

    Impact resistance

    30 grams, 11 milliseconds (EN 60947-5-3)