Yuanben Sensor Engaged in magnetoelectric sensor design & production, a professional high-tech magnetic sensor manufacturer.
MPSS-0712-3054 non-contact magnetically coded saferty switch
I Feature
Interlocking guards are available where additional security is required.
No door lock required.
Harsh environments such as vibration,water, or dust.
II Application
Food and beverage packaging/filling.
Dairy, pharmaceutical, papermaking industries.
Can forming and filling (Aluminum,steel, plastic)
Semiconductor Manufacturing/Assembly
III Technical Parameter
Operation |
Coded non-contact type |
Switches mode |
2 x N/O + 1 x N/C |
Safety contact working distance |
7mm switch on/ 12mm switch off |
Safety contact rating DC: |
24VDC/400mA |
Auxiliary contact rating DC: |
24VDC/400mA |
External fuse(when not using SCU-1) |
400mA |
Dimensions |
See drawing |
IP protection grade level |
IP67 protection grade |
Cable length |
Max.100 meter |
Working temp.range |
-25°C to +55°C |
Storage temp. Range |
-25°C to +55°C |
Mounting |
Target to target |
Construction |
Yellow PBT or 316 grade stainless steel resin filled |
Standards EN ISO 13849-1 Safety of machinery-safety-related parts of control systems. EN ISO 62061 Safety of machinery-Functional safety related electrical,electronic and Programmable electronic control systems EN 60204 Safety of Machinery Electrical equipment for machines EN 60947-5-1 Low voltage switch gear and control gear EN 14119 Safety of machinery interlocking devices associated with guards EN 60947-5-3 Mechanical safety specifications for low voltage switch gear and control gear. |
Light Emitting diode |
S1 series |
Power |
Running |
S2 series |
|
Power-off |
Light off |
Light off |
Light off |
Light off |
Light off |
Turn on S1 and S2’s power supply,Switch on |
Red |
Light off |
Red |
Light off |
Light off |
Power on S1 has been closed. |
Green |
Yellow |
Red |
Light off |
Light off |
Power on,S1 and S2 has been closed. |
|
Yellow |
Red |
Green |
Yellow |
IV LED Indication
Mount the safety switch,do not use the safety switch as a stop. A 1mm gap when closed provides the best results. Mount the switch to the frame and the actuator to the edge of the door opening. Always try to mount the switch on non-ferrous materials.(Ferrous materials may shorten the switching distance.)
V Operation
The MPSS safety switch features up to 2 N/O +1 N/C bi-directional solid state outputs and built-in LEDs for indication.When mounted on a machine guard,energized,and the switch and actuator are within the specified operating range,the N/O output will close and the N/C output will open.
When the actuator moves out of the operating range,the N/O output will open and the N/C ouput will closse.(See LED indication.The MPSS safety switch and the actuator have a switching distance of 7mm and can approach each other from most angles.The target on the printed face of the switch and actuator as a stop,leave a 1-2 mm gap for best operation and tolerance of machine guard vibration.
Switch Characteristics.
VI Electircal Definition
Cable
Connectors
Can be customized upon request。
For more information, please contact us.
Get in touch with us